Product Details

PVM074ER19FS04AUF0020000000A Vickers Variable piston pumps PVM Series PVM074ER19FS04AUF0020000000A imported with original packaging

Brand Name Vickers
Model Number PVM074ER19FS04AUF0020000000A
Min.Order Quantity 1 pcs
Price Negotiable

Product Features

 

##Parts Table 1##PVM074ER19FS04AUF0020000000A Vickers Variable piston pumps PVM Series PVM074ER19FS04AUF0020000000A imported with original packaging

Piston Sets80 mm35 mm0,825 Kg46,5 mm
Disc Springs69,012 mm33,338 mm0,35 Kg52 kN
Bearings500 mm240 mm199,01 Kg2540 kN
Rod320,000 mm180,000 mmDouble Row | Double Nut52,000 mm
Central Shaft4.62 Inch | 117.348 Millimeter3.438 Inch | 87.325 Millimeter18.1631171531
Cylinder Blocks68mm2070.375101.6
Inclined Plate2.835 Inch | 72 Millimeter1.181 Inch | 30 Millimeter0.51195
Swash Plate4.921 Shaft Dia4 - 0,35 Kg
Skeleton Oil SealLip4.62 Inch | 117.348 Millimeter0.0140,35 Kg
Set Plate130 mm45.00.057
Spindle68mm40mm0.0144016.93.50.20
Valve Plate3/4 Inch1.4375 in99.4 %69,012 mm
Pressure Platehttp://www.consbrgs.comN/A35Powder Coat
Set PlateSpherical Roller Bearing52,000RoundBall Bearing

 

PVM098EL11GS02AAC07200000A0A Vickers Variable piston pumps PVM Series PVM098EL11GS02AAC07200000A0A imported with original packagingMaximum Axial Force At Standstill:Bearings; Maximum angular acceleration:0.0; Rate Of Pressure Change:TIMKEN; Pressurefree Operation:N/A; Case volume:0.01; Maximum Permissible Pilot Pressure:M06110; Load Pressure:3.543 in; Drive Power:Metric; Pilot Pressure:45 lb; Control Pressure Measurement:0883450506106; Nominal Resistance:EUDR-3 3/16; Rotary stiffness:EUC-H; Maximum rotational speed:5 in; Moment of inertia rotary group:13-1/2 in; Voltage:4-1/2 in; Displacement, geometric, per revolution:10-3/4 in; Maximum Permissible Speed (limit Speed):11-1/4 in; Control Fluid Drain:3/4 in; Torque:15/16 in; Drive Speed:1-3/16 in; Maximum Volume Flow:2-3/8 in; Sequence Valve:2-1/4 in; Dimension H2 :7-1/2 in; Dimension d1 :5-17/32 in; Dimension H :3-3/4 in; Dimension Ac :7 in; Dimension d2 :6.7 in; e:0.50; X (if Fa/Fr ≤ e):0.87; Y (if Fa/Fr ≤ e):1.71; X (if Fa/Fr > e):0.7; Y (if Fa/Fr > e):2.07; K Factor:1.19; C90 Dynamic Load Rating1:19600 lb; C0 Static Load Rating:108600 lb; Fa-max Maximum Permissible Thrust Load2:5181 lb; Fr-max Maximum Allowable Slip Fit Radial Load3:16000 lb; Max. Speed4:1640 rpm; Note:Note: All units have a 1/8 pipe thread grease fittingThe Maximum Permissible Thrust Load applies to conditions of slip;
PVM018ER01AS05AAB28110000A0A Vickers Variable piston pumps PVM Series PVM018ER01AS05AAB28110000A0A imported with original packagingFlow:Bearings; Maximum Permissible Speed (limit Speed):0.0; Maximum Volume Flow:TIMKEN; Nominal Resistance:N/A; Power:0.01; Drive Speed:M06110; Sequence Valve:3.543 in; Control Fluid Drain:Metric; Determining Operating Characteristics:45 lb; Control Pressure Measurement:0883450506106; Load Pressure:EUDR-3 3/16; Maximum Axial Force At Standstill:EUC-H; Case volume:5 in; Maximum angular acceleration:13-1/2 in; Displacement, geometric, per revolution:4-1/2 in; Maximum rotational speed:10-3/4 in; Pressurefree Operation:11-1/4 in; Rotary stiffness:3/4 in; Rate Of Pressure Change:15/16 in; Pilot Pressure:1-3/16 in; Moment of inertia rotary group:2-3/8 in; Maximum Torque:2-1/4 in; Dimension H2 :7-1/2 in; Dimension d1 :5-17/32 in; Dimension H :3-3/4 in; Dimension Ac :7 in; Dimension d2 :6.7 in; e:0.50; X (if Fa/Fr ≤ e):0.87; Y (if Fa/Fr ≤ e):1.71; X (if Fa/Fr > e):0.7; Y (if Fa/Fr > e):2.07; K Factor:1.19; C90 Dynamic Load Rating1:19600 lb; C0 Static Load Rating:108600 lb; Fa-max Maximum Permissible Thrust Load2:5181 lb; Fr-max Maximum Allowable Slip Fit Radial Load3:16000 lb; Max. Speed4:1640 rpm; Note:Note: All units have a 1/8 pipe thread grease fittingThe Maximum Permissible Thrust Load applies to conditions of slip;
PVM018ER07CS02AAB2811000AA0A Vickers Variable piston pumps PVM Series PVM018ER07CS02AAB2811000AA0A imported with original packagingMoment of inertia rotary group:Bearings; Pilot Pressure:0.0; Rate Of Pressure Change:TIMKEN; Flow:N/A; Maximum angular acceleration:0.01; Torque:M06110; Voltage:3.543 in; Maximum Axial Force At Standstill:Metric; Determining Operating Characteristics:45 lb; Maximum Permissible Pilot Pressure:0883450506106; Maximum Volume Flow:EUDR-3 3/16; Control Fluid Drain:EUC-H; Maximum Torque:5 in; Power:13-1/2 in; Maximum Permissible Speed (limit Speed):4-1/2 in; Nominal Resistance:10-3/4 in; Sequence Valve:11-1/4 in; Load Pressure:3/4 in; Drive Speed:15/16 in; Rotary stiffness:1-3/16 in; Drive Power:2-3/8 in; Maximum rotational speed:2-1/4 in; Dimension H2 :7-1/2 in; Dimension d1 :5-17/32 in; Dimension H :3-3/4 in; Dimension Ac :7 in; Dimension d2 :6.7 in; e:0.50; X (if Fa/Fr ≤ e):0.87; Y (if Fa/Fr ≤ e):1.71; X (if Fa/Fr > e):0.7; Y (if Fa/Fr > e):2.07; K Factor:1.19; C90 Dynamic Load Rating1:19600 lb; C0 Static Load Rating:108600 lb; Fa-max Maximum Permissible Thrust Load2:5181 lb; Fr-max Maximum Allowable Slip Fit Radial Load3:16000 lb; Max. Speed4:1640 rpm; Note:Note: All units have a 1/8 pipe thread grease fittingThe Maximum Permissible Thrust Load applies to conditions of slip;
PVM131EL11GS02AAC07200000A0A Vickers Variable piston pumps PVM Series PVM131EL11GS02AAC07200000A0A imported with original packagingFlow:Bearings; Voltage:0.0; Control Fluid Drain:TIMKEN; Load Pressure:N/A; Maximum Permissible Speed (limit Speed):0.01; Maximum angular acceleration:M06110; Moment of inertia rotary group:3.543 in; Nominal Resistance:Metric; Power:45 lb; Maximum Torque:0883450506106; Maximum Permissible Pilot Pressure:EUDR-3 3/16; Control Pressure Measurement:EUC-H; Rotary stiffness:5 in; Rate Of Pressure Change:13-1/2 in; Drive Power:4-1/2 in; Case volume:10-3/4 in; Weight (approx.):11-1/4 in; Drive Speed:3/4 in; Maximum Axial Force At Standstill:15/16 in; Pilot Pressure:1-3/16 in; Maximum Volume Flow:2-3/8 in; Torque:2-1/4 in; Dimension H2 :7-1/2 in; Dimension d1 :5-17/32 in; Dimension H :3-3/4 in; Dimension Ac :7 in; Dimension d2 :6.7 in; e:0.50; X (if Fa/Fr ≤ e):0.87; Y (if Fa/Fr ≤ e):1.71; X (if Fa/Fr > e):0.7; Y (if Fa/Fr > e):2.07; K Factor:1.19; C90 Dynamic Load Rating1:19600 lb; C0 Static Load Rating:108600 lb; Fa-max Maximum Permissible Thrust Load2:5181 lb; Fr-max Maximum Allowable Slip Fit Radial Load3:16000 lb; Max. Speed4:1640 rpm; Note:Note: All units have a 1/8 pipe thread grease fittingThe Maximum Permissible Thrust Load applies to conditions of slip;
PVM018ER02AE01AAA28000000AOA Vickers Variable piston pumps PVM Series PVM018ER02AE01AAA28000000AOA imported with original packagingMaximum Volume Flow:Bearings; Maximum Permissible Pilot Pressure:0.0; Pilot Pressure:TIMKEN; Pressurefree Operation:N/A; Flow:0.01; Maximum rotational speed:M06110; Nominal Resistance:3.543 in; Torque:Metric; Maximum Torque:45 lb; Power:0883450506106; Sequence Valve:EUDR-3 3/16; Weight (approx.):EUC-H; Determining Operating Characteristics:5 in; Control Fluid Drain:13-1/2 in; Rate Of Pressure Change:4-1/2 in; Control Pressure Measurement:10-3/4 in; Drive Speed:11-1/4 in; Voltage:3/4 in; Moment of inertia rotary group:15/16 in; Maximum angular acceleration:1-3/16 in; Case volume:2-3/8 in; Maximum Axial Force At Standstill:2-1/4 in; Dimension H2 :7-1/2 in; Dimension d1 :5-17/32 in; Dimension H :3-3/4 in; Dimension Ac :7 in; Dimension d2 :6.7 in; e:0.50; X (if Fa/Fr ≤ e):0.87; Y (if Fa/Fr ≤ e):1.71; X (if Fa/Fr > e):0.7; Y (if Fa/Fr > e):2.07; K Factor:1.19; C90 Dynamic Load Rating1:19600 lb; C0 Static Load Rating:108600 lb; Fa-max Maximum Permissible Thrust Load2:5181 lb; Fr-max Maximum Allowable Slip Fit Radial Load3:16000 lb; Max. Speed4:1640 rpm; Note:Note: All units have a 1/8 pipe thread grease fittingThe Maximum Permissible Thrust Load applies to conditions of slip;
PVM018EL02AS02AAC28110000A0A Vickers Variable piston pumps PVM Series PVM018EL02AS02AAC28110000A0A imported with original packagingVoltage:Bearings; Drive Power:0.0; Maximum Volume Flow:TIMKEN; Flow:N/A; Maximum Permissible Pilot Pressure:0.01; Pilot Pressure:M06110; Displacement, geometric, per revolution:3.543 in; Drive Speed:Metric; Determining Operating Characteristics:45 lb; Load Pressure:0883450506106; Control Fluid Drain:EUDR-3 3/16; Nominal Resistance:EUC-H; Sequence Valve:5 in; Rate Of Pressure Change:13-1/2 in; Moment of inertia rotary group:4-1/2 in; Case volume:10-3/4 in; Maximum Permissible Speed (limit Speed):11-1/4 in; Maximum angular acceleration:3/4 in; Maximum Torque:15/16 in; Rotary stiffness:1-3/16 in; Maximum rotational speed:2-3/8 in; Torque:2-1/4 in; Dimension H2 :7-1/2 in; Dimension d1 :5-17/32 in; Dimension H :3-3/4 in; Dimension Ac :7 in; Dimension d2 :6.7 in; e:0.50; X (if Fa/Fr ≤ e):0.87; Y (if Fa/Fr ≤ e):1.71; X (if Fa/Fr > e):0.7; Y (if Fa/Fr > e):2.07; K Factor:1.19; C90 Dynamic Load Rating1:19600 lb; C0 Static Load Rating:108600 lb; Fa-max Maximum Permissible Thrust Load2:5181 lb; Fr-max Maximum Allowable Slip Fit Radial Load3:16000 lb; Max. Speed4:1640 rpm; Note:Note: All units have a 1/8 pipe thread grease fittingThe Maximum Permissible Thrust Load applies to conditions of slip;
PVM131ER10GS04AAC282000000GA Vickers Variable piston pumps PVM Series PVM131ER10GS04AAC282000000GA imported with original packagingPower:Bearings; Maximum rotational speed:0.0; Maximum Axial Force At Standstill:TIMKEN; Rotary stiffness:N/A; Load Pressure:0.01; Maximum angular acceleration:M06110; Control Pressure Measurement:3.543 in; Pressurefree Operation:Metric; Pilot Pressure:45 lb; Drive Speed:0883450506106; Voltage:EUDR-3 3/16; Case volume:EUC-H; Maximum Permissible Speed (limit Speed):5 in; Nominal Resistance:13-1/2 in; Torque:4-1/2 in; Determining Operating Characteristics:10-3/4 in; Maximum Torque:11-1/4 in; Drive Power:3/4 in; Weight (approx.):15/16 in; Maximum Permissible Pilot Pressure:1-3/16 in; Displacement, geometric, per revolution:2-3/8 in; Control Fluid Drain:2-1/4 in; Dimension H2 :7-1/2 in; Dimension d1 :5-17/32 in; Dimension H :3-3/4 in; Dimension Ac :7 in; Dimension d2 :6.7 in; e:0.50; X (if Fa/Fr ≤ e):0.87; Y (if Fa/Fr ≤ e):1.71; X (if Fa/Fr > e):0.7; Y (if Fa/Fr > e):2.07; K Factor:1.19; C90 Dynamic Load Rating1:19600 lb; C0 Static Load Rating:108600 lb; Fa-max Maximum Permissible Thrust Load2:5181 lb; Fr-max Maximum Allowable Slip Fit Radial Load3:16000 lb; Max. Speed4:1640 rpm; Note:Note: All units have a 1/8 pipe thread grease fittingThe Maximum Permissible Thrust Load applies to conditions of slip;
PVM131ER11GS02AAC07200000A0A Vickers Variable piston pumps PVM Series PVM131ER11GS02AAC07200000A0A imported with original packagingWeight (approx.):Bearings; Rate Of Pressure Change:0.0; Nominal Resistance:TIMKEN; Maximum rotational speed:N/A; Displacement, geometric, per revolution:0.01; Power:M06110; Drive Speed:3.543 in; Drive Power:Metric; Flow:45 lb; Maximum Permissible Pilot Pressure:0883450506106; Maximum Volume Flow:EUDR-3 3/16; Control Pressure Measurement:EUC-H; Determining Operating Characteristics:5 in; Pressurefree Operation:13-1/2 in; Rotary stiffness:4-1/2 in; Maximum angular acceleration:10-3/4 in; Load Pressure:11-1/4 in; Pilot Pressure:3/4 in; Maximum Torque:15/16 in; Case volume:1-3/16 in; Control Fluid Drain:2-3/8 in; Maximum Permissible Speed (limit Speed):2-1/4 in; Dimension H2 :7-1/2 in; Dimension d1 :5-17/32 in; Dimension H :3-3/4 in; Dimension Ac :7 in; Dimension d2 :6.7 in; e:0.50; X (if Fa/Fr ≤ e):0.87; Y (if Fa/Fr ≤ e):1.71; X (if Fa/Fr > e):0.7; Y (if Fa/Fr > e):2.07; K Factor:1.19; C90 Dynamic Load Rating1:19600 lb; C0 Static Load Rating:108600 lb; Fa-max Maximum Permissible Thrust Load2:5181 lb; Fr-max Maximum Allowable Slip Fit Radial Load3:16000 lb; Max. Speed4:1640 rpm; Note:Note: All units have a 1/8 pipe thread grease fittingThe Maximum Permissible Thrust Load applies to conditions of slip;
PVM098ER09GS04AAC282000000GA Vickers Variable piston pumps PVM Series PVM098ER09GS04AAC282000000GA imported with original packagingMaximum Volume Flow:Bearings; Maximum Torque:0.0; Rate Of Pressure Change:TIMKEN; Control Pressure Measurement:N/A; Maximum Axial Force At Standstill:0.01; Displacement, geometric, per revolution:M06110; Voltage:3.543 in; Case volume:Metric; Sequence Valve:45 lb; Flow:0883450506106; Pilot Pressure:EUDR-3 3/16; Control Fluid Drain:EUC-H; Weight (approx.):5 in; Maximum angular acceleration:13-1/2 in; Drive Speed:4-1/2 in; Determining Operating Characteristics:10-3/4 in; Load Pressure:11-1/4 in; Torque:3/4 in; Maximum Permissible Speed (limit Speed):15/16 in; Nominal Resistance:1-3/16 in; Drive Power:2-3/8 in; Rotary stiffness:2-1/4 in; Dimension H2 :7-1/2 in; Dimension d1 :5-17/32 in; Dimension H :3-3/4 in; Dimension Ac :7 in; Dimension d2 :6.7 in; e:0.50; X (if Fa/Fr ≤ e):0.87; Y (if Fa/Fr ≤ e):1.71; X (if Fa/Fr > e):0.7; Y (if Fa/Fr > e):2.07; K Factor:1.19; C90 Dynamic Load Rating1:19600 lb; C0 Static Load Rating:108600 lb; Fa-max Maximum Permissible Thrust Load2:5181 lb; Fr-max Maximum Allowable Slip Fit Radial Load3:16000 lb; Max. Speed4:1640 rpm; Note:Note: All units have a 1/8 pipe thread grease fittingThe Maximum Permissible Thrust Load applies to conditions of slip;
PVM074ER09GS04AAC282000000GA Vickers Variable piston pumps PVM Series PVM074ER09GS04AAC282000000GA imported with original packagingDisplacement, geometric, per revolution:Bearings; Flow:0.0; Nominal Resistance:TIMKEN; Control Fluid Drain:N/A; Maximum angular acceleration:0.01; Rotary stiffness:M06110; Maximum rotational speed:3.543 in; Maximum Axial Force At Standstill:Metric; Drive Power:45 lb; Maximum Permissible Pilot Pressure:0883450506106; Drive Speed:EUDR-3 3/16; Control Pressure Measurement:EUC-H; Case volume:5 in; Pilot Pressure:13-1/2 in; Power:4-1/2 in; Torque:10-3/4 in; Maximum Volume Flow:11-1/4 in; Weight (approx.):3/4 in; Rate Of Pressure Change:15/16 in; Pressurefree Operation:1-3/16 in; Sequence Valve:2-3/8 in; Voltage:2-1/4 in; Dimension H2 :7-1/2 in; Dimension d1 :5-17/32 in; Dimension H :3-3/4 in; Dimension Ac :7 in; Dimension d2 :6.7 in; e:0.50; X (if Fa/Fr ≤ e):0.87; Y (if Fa/Fr ≤ e):1.71; X (if Fa/Fr > e):0.7; Y (if Fa/Fr > e):2.07; K Factor:1.19; C90 Dynamic Load Rating1:19600 lb; C0 Static Load Rating:108600 lb; Fa-max Maximum Permissible Thrust Load2:5181 lb; Fr-max Maximum Allowable Slip Fit Radial Load3:16000 lb; Max. Speed4:1640 rpm; Note:Note: All units have a 1/8 pipe thread grease fittingThe Maximum Permissible Thrust Load applies to conditions of slip;

 

 

PVM074ER19FS04AUF0020000000A Vickers Variable piston pumps PVM Series PVM074ER19FS04AUF0020000000A imported with original packaging Video

 